SQUARED XALD222 Control station, Ha

Manufacturer: Square-D / Schneider | Catalog # XALD222 | Cooper Electric Part # 945133

$53.66 /ea
ea
Log in or register to view your price, purchase history, and more!
Out of stock, please contact your sales representative for availability, pricing and lead times
This Harmony XALD dark grey control station is ideal to control simple hoists. This dark grey control station enables machine builders to easily add control and signalling functionality on their machines, with permanent modifications or damage to their machine body. It is designed for simple and mass production machines, textiles, packaging, handling small lifting systems, control of garage doors, rolling shutters, smoke extraction vents. It is compatible with Harmony XB5 range push buttons, switches and pilot lights. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments. It is also resistant to chemicals and offers double insulation.

Technical Information

Action
Slow-break
Actuator
White ''up arrow'' 1 NO - black ''down arrow'' 1 NO;2 flush push-buttons
Amperage
6 Amp 120 V, AC-15, A600 EN/IEC 60947-5-1-3 Amp 240 V, AC-15, A600 EN/IEC 60947-5-1-1.2 Amp 600 V, AC-15, A600 EN/IEC 60947-5-1-0.55 Amp 125 V, DC-13, Q600 EN/IEC 60947-5-1-0.27 Amp 250 V, DC-13, Q600 EN/IEC 60947-5-1-0.1 Amp 600 V, DC-13, Q600 EN/IEC 60947-5-1
Applications
For XB5 22 mm control and signalling units
Cable Entry
14-14 mm
Contact Material
Silver Alloy
Enclosure
NEMA 13-NEMA 4X
Material
Polycarbonate
Net Weight
0.233 kg
Operating Force
3.8 N
Operating Temperature
-40-70 Adegrees C
Standard
CSA C22.2 No 14,IEC 60947-1,IEC 60947-5-1,IEC 60947-5-4,IEC 60947-5-5,JIS C8201-1,JIS C8201-5-1,UL 508
Storage Temperature
-40-70 degrees C
TC Connection
SCREW CLAMP TERMINALS, <= 2 X 1.5 MMA WITH CABLE END EN/IEC 60947-1-SCREW CLAMP TERMINALS, >= 1 X 0.22 MMA WITHOUT CABLE END EN/IEC 60947-1
Type
Complete control station

Manufacturer Information

Brand
Schneider Electric
Sub Brand
XALD

General Product Info

12-Digit UPC
785901618690
GTiN
03389110114164
Product UPC
78590161869
Weight
0.233 kg

Dimensions

Warranty Length
18 mth

Certifications and Compliance

CA Prop65 Warning
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Country of Origin
France
Connections Terminals
  • screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1
  • screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60
Color Of Base Of Enclosure
  • light grey RAL 7035)
IE Rated Operational Current
  • 6 A 120 V, AC-15, A600 IEC 60947-5-1
  • 3 A 240 V, AC-15, A600 IEC 60947-5-1
  • 3 A 240 V, AC-15, A600 IEC 60947
ITH Conventional Free Air Thermal Current
  • 10 A IEC 60947-5-1
IP Degree Of Protection
  • IP66 IEC 60529
  • IP67
  • IP69
  • IP69K
Shape Of Screw Head
  • cross Philips no 1
  • cross pozidriv No 1
  • slotted flat Ø 4 mm
  • slotted flat Ø 5.5 mm
Carbon Footprint Of The Installation Phase A5
  • 0.0014054967
  • 0 kg CO2 eq.
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 0 kg CO2 eq.
  • 0.0439968166
Cable Entry
  • 2 knock-outs for cable entry 14-14 mm
  • 2 knock-outs for Pg 13 cable gland and ISO M20 12-12 mm
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 2 kg CO2 eq.
  • 1.5165171097
Electrical Shock Protection Class
  • class II conforming to IEC 60536
Nema Degree Of Protection
  • NEMA 13
  • NEMA 4X
UI Rated Insulation Voltage
  • 600 V 3)IEC 60947-1
Accessories
  • ZBZ28
  • ZBY2101
  • ZB4FBZ014
Electrical Durability
  • 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
  • 1000000 cycles, AC-15, 2 A 230 V 36
Operating Force
  • 3.8 N NO changing electrical state
Vibration Resistance
  • 5 gn (f= 12-500 Hz) conforming to IEC 60068-2-6
Market Segmentation
  • Commercial
  • Industrial
Color Of Cover
  • dark grey RAL 7016)
Persona Type Names
  • Charge Point Operator
  • End User
  • Contractor
  • Original Equipment Manufacturer
  • OEM - Control Panelbuilder
  • Panel Builder
  • Electrician
  • System Integrator
  • IT Channel Partner
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 0.1 kg CO2 eq.
  • 0.1218928
Accessory Products
  • ZBZ28
  • ZBY2101
  • ZB4FBZ014
Persona Type Ids
  • BM9
  • EU
  • LC
  • OM
  • OM8
  • PB
  • SC
  • SI
  • VR
Carbon Footprint Of The Distribution Phase A4
  • 0.0300628766
  • 0 kg CO2 eq.
Tightening Torque
  • 0.8-1.2 N.m IEC 60947-1
Resistance To High Pressure Washer
  • 7000000 Pa 55 °C 0.1 m
Short Circuit Protection
  • 10 A cartridge fuse gG IEC 60947-5-1
Control Station Composition
  • 1 flush push-button, black 1 NO, white down arrow
  • 1 fl
Color Of Marking
  • white marking when green, red or black caps
  • black marking when white caps
Operating Travel
  • 2.6 mm NO changing electrical state)
  • 4.3 mm total travel)
Market Segmentation Id
  • COMMERCIAL
  • INDUSTRIAL
Electrical Reliability
  • ? < 10exp(-6) 5 V 1 mA IEC 60947-5-4
  • ? < 10exp(-8) 17 V 5 mA IEC 60947-5-4
  • ? < 10exp(-8) 17 V 5 mA IEC 60
Shock Resistance
  • 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27
  • 50 gn 11 ms) half sine wave ac
UIMP Rated Impulse Withstand Voltage
  • 6 kV IEC 60947-1