Product image for Square D XACA471 600 VAC 10 Amp 1NO NEMA 4/4X/5 Yellow Polypropylene Pendant Station
Image thumbnail 0
Image thumbnail 2
Image thumbnail 3
Image thumbnail 4
Image thumbnail 5
Image thumbnail 6
Image thumbnail 7

Email

Square D XACA471 600 VAC 10 Amp 1NO NEMA 4/4X/5 Yellow Polypropylene Pendant Station

Manufacturer: Square-D / Schneider | Catalog # XACA471 | Cooper Electric Part # 607302

$247.70 /ea
ea
Log in or register to view your price, purchase history, and more!
Out of stock, please contact your sales representative for availability, pricing and lead times
This Harmony XAC, pendant station is ideal to control single speed hoisting applications. This pistol grip shaped pendant control station is ideal for direct control with heavy work gloves of mechanical handling applications such as overhead cranes, tower cranes, fixed hoists and beam hoists. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP65, making it ideal for operation in harsh environments. It has a solid rubber grommet junction with cable, for maximum water tightness. Its ergonomic pistol grip allows single handed control of your hoist and crane.

Technical Information

Applications
Control circuit;Control of single speed hoist motor
Cable Entry
8-26 mm
Contact Rating
Slow-break
Enclosure
Polypropylene
Enclosure Material
Polypropylene
Enclosure Type
Complete Ready For Use
Net Weight
0.625 kg
Operating Force
10-10 N
Operating Temperature
-13158 degrees F (-2570 degrees C)
Standard
CSA C22.2 No 14,EN/IEC 60204-32,EN/IEC 60947-5-1,UL 508
Storage Temperature
-40-70 degrees C
TC Connection
SCREW CLAMP TERMINALS, 1 X 0.5...1 X 2.5 MMA WITHOUT CABLE END-SCREW CLAMP TERMINALS, 1 X 0.5...2 X 1.5 MMA WITH CABLE END
Type
Double insulated;Pendant control station
Wattage
40 Watt DC-13 1000000 CYCLES 60 CYC/MN 120 Volt 0.5 INDUCTIVE IEC 60947 - 5-1 APPENDIX C-48 Watt DC-13 1000000 CYCLES 60 CYC/MN 48 Volt 0.5 INDUCTIVE IEC 60947 - 5-1 APPENDIX C-65 Watt DC-13 1000000 CYCLES 60 CYC/MN 24 Volt 0.5 INDUCTIVE IEC 60947 - 5-1 APPENDIX C

Manufacturer Information

Brand
Schneider Electric
Sub Brand
XACA

General Product Info

12-Digit UPC
389110645104
GTiN
03389110645101
Product UPC
78590109331
Weight
0.625 kg

Dimensions

Warranty Length
18 mth

Certifications and Compliance

CA Prop65 Warning
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Certifications
CCC,GOST
Country of Origin
Czechia
Connections Terminals
  • screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end
  • screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end
Overvoltage Category
  • class II conforming to IEC 61140
IP Degree Of Protection
  • IP65 conforming to IEC 60529
Prop 65
  • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Control Button Type
  • first push-button 1 NO raise, slow
  • second push-button 1 NO lower, slow
  • fourth push-button 1 NO left, slow
  • third push-button 1 NO right, slow
Carbon Footprint Of The Installation Phase A5
  • 0.0034095816
  • 0 kg CO2 eq.
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 0.6 kg CO2 eq.
  • 0.6177377622
Cable Entry
  • rubber sleeve with stepped entry 8-26 mm
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 3 kg CO2 eq.
  • 3.3862459207
UI Rated Insulation Voltage
  • 600 V 3)
Rated Operational Power In W
  • 40 W DC-13 1000000 cycles 60 cyc/mn 120 V 0.5 inductive IEC 60947-5-1 appendix C
  • 48 W DC-13 1000000 cycles 60 cyc/mn 48 V 0.5 inductive IEC 60947-5-1 appendix C
  • 65 W DC-13 1000000 cycles 60 cyc/mn 24 V 0.5 inductive IEC 60947-5-1 appendix C
Operating Force
  • 10-10 N push-button
Vibration Resistance
  • 15 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
Market Segmentation
  • Commercial
  • Industrial
Terminal Identifier
  • (13-14)NO
  • (11-12)NC
Persona Type Names
  • Charge Point Operator
  • End User
  • Contractor
  • Original Equipment Manufacturer
  • OEM - Control Panelbuilder
  • Panel Builder
  • Electrician
  • System Integrator
  • IT Channel Partner
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 0 kg CO2 eq.
  • 0
Persona Type Ids
  • BM9
  • EU
  • LC
  • OM
  • OM8
  • PB
  • SC
  • SI
  • VR
Carbon Footprint Of The Distribution Phase A4
  • 0.1430651515
  • 0.1 kg CO2 eq.
Short Circuit Protection
  • 10 A fuse protection cartridge gG
Contact Code Designation
  • A600 AC-15, Ue = 240 V, Ie = 3 A IEC 60947-5-1 appendix A
  • A600 AC-15, Ue = 600 V, Ie = 1.2 A IEC 60947-5-1 appendix A
  • Q600 DC-13, Ue = 250 V, Ie = 0.27 A IEC 60947-5-1 appendix A
  • Q600 DC-13, Ue = 600 V, Ie = 0.1 A IEC 60947-5-1 appendix A
Market Segmentation Id
  • COMMERCIAL
  • INDUSTRIAL
Shock Resistance
  • 100 gn IEC 60068-2-27
Product Compatibility
  • ZB2BE101 for each direction
UIMP Rated Impulse Withstand Voltage
  • 6 kV IEC 60947-1



Compare