SQD HDL36015T Circuit breaker, Powe

Manufacturer: Square-D / Schneider | Catalog # HDL36015T | Cooper Electric Part # 512261

$1,088.00 /ea
ea
Log in or register to view your price, purchase history, and more!
Out of stock, please contact your sales representative for availability, pricing and lead times
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units

Technical Information

Amperage
15 Amp
Frame
D
Interrupt Rating
14, 18, 20, 25 kAIC
Line Rated Current
15-15 A
Mounting Type
Unit Mount Lug)
Net Weight
2.2 kg
Number of Poles
3 Pole
Operating Temperature
40 Adegrees C
Standard
CSA,IEC 60947-2,NEMA,NOM-003-SCFI-2000,UL
Storage Temperature
-50-85 degrees C
Strip Length
16 mm
TC Connection
AWG 14...AWG 3/0 ALUMINIUM/COPPER,LUGS LOAD-LUGS LINE
Trip Point
750-750 A
Trip Range
15 A,350 A,750 A
Trip Type
THERMAL-MAGNETIC
Type
CIRCUIT BREAKER
Voltage
250 Volt

Manufacturer Information

Brand
Square D

General Product Info

12-Digit UPC
785901550013
Color
Black
GTiN
00785901550013
Product UPC
78590155001
Weight
2.2 kg

Dimensions

Depth
3.39 in
Height
6.42 in
Length
16 mm
Warranty Length
18 mth
Width
4.09 in

Certifications and Compliance

CA Prop65 Warning
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go t
Certifications
CSA,NOM,UL
Country of Origin
USA
Installed Device
  • trip unit field installable
Communication Interface
  • Modbus
  • Ethernet
Uimp Rated Impulse Withstand Voltage
  • 8 kV IEC 60947-2
Mounting Mode
  • unit mount lug)
Prop 65
  • WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go t
Carbon Footprint Of The Installation Phase A5
  • 0.01827056403892661
  • 0 kg CO2 eq.
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 3 kg CO2 eq.
  • 3.391969932864633
Standards
  • UL
  • CSA
  • NEMA
  • NOM-003-SCFI-2000
  • IEC 60947-2
Ue Rated Operational Voltage
  • 690 V AC 50/60 Hz IEC 60947-3
Ui Rated Insulation Voltage
  • 750 V IEC 60947-2
Ip Degree Of Protection
  • front cover IP40 IEC 60529
Electrical Connection
  • lugs, line
  • lugs, load
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 9 kg CO2 eq.
  • 9.231241412339646
Ics Rated Service Breaking Capacity
  • 25 kA 220/240 V AC 50/60 Hz IEC 60947-2
  • 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2
  • 18 kA 380/
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 150 kg CO2 eq.
  • 149.50336784240147
Number Of Slots
  • 2 auxiliary switch OF plug-in)
  • 1 alarm switch SD plug-in)
  • 1 overcurrent trip swi
Accessory Products
  • VTRIPHJ
Carbon Footprint Of The Distribution Phase A4
  • 0.3812916237468922
  • 0.4 kg CO2 eq.
Tightening Torque
  • 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10)
  • 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Operating Altitude
  • < 6561.68 ft (2000 m) without derating
  • 5000 m with derating
Suitability For Isolation
  • yes IEC 60947-2
AWG Gauge
  • AWG 14...AWG 3/0 aluminium/copper terminal
Local Signalling
  • switched off (OFF) 1 trip indicator green)
Product Certifications
  • UL
  • CSA
  • NOM