Square D LC1D50BD 600 VAC 50 Amp 3-Pole 1NO 1NC Screw Terminal Full Voltage Non-Reversing IEC Contactor

Manufacturer: Square-D / Schneider | Catalog # LC1D50BD | Cooper Electric Part # 376870

$399.96/ea
ea
Log in or register to view your price, purchase history, and more!
Out of stock, please contact your sales representative for availability, pricing and lead times
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Technical Information

Applications
Motor control;Resistive load
Coil Voltage
24 V DC,POWER CIRCUIT <= 690 V AC 25...400 HZ
Contact Configuration
1 NO + 1 NC,3 NO
Contact Rating
10 A 60 AC CONTROL CIRCUIT-80 A 60 AC POWER CIRCUIT
Net Weight
2.185 kg
Operating Cycles
3600 cyc/h 60 C
Operating Temperature
-40-70 Adegrees C AT UC,-5-60 Adegrees C
Size
6.93 in
Standard
CSA C22.2 No 14,EN 60947-4-1,EN 60947-5-1,IEC 60947-4-1,IEC 60947-5-1
Storage Temperature
-60-80 degrees C
TC Connection
CONTROL CIRCUIT SCREW CLAMP TERMINALS 1 1-4 MMARIGID-CONTROL CIRCUIT SCREW CLAMP TERMINALS 2 1-4 MMARIGID-CONTROL CIRCUIT SCREW CLAMP TERMINALS 1 1-4 MMAFLEXIBLE WITHOUT CABLE END-CONTROL CIRCUIT SCREW CLAMP TERMINALS 2 1-4 MMAFLEXIBLE WITHOUT CABLE END-CONTROL CIRCUIT SCREW CLAMP TERMINALS 1 1-2.5 MMAFLEXIBLE WITH CABLE END-CONTROL CIRCUIT SCREW CLAMP TERMINALS 2 1-2.5 MMAFLEXIBLE WITH CABLE END-POWER CIRCUIT SCREW TERMINALS 1 2.5-25 MMARIGID-POWER CIRCUIT SCREW TERMINALS 2 2.5-16 MMARIGID-POWER CIRCUIT SCREW TERMINALS 1 2.5-25 MMAFLEXIBLE WITHOUT CABLE END-POWER CIRCUIT SCREW TERMINALS 2 2.5-16 MMAFLEXIBLE WITHOUT CABLE END-POWER CIRCUIT SCREW TERMINALS 1 2.5-25 MMAFLEXIBLE WITH CABLE END-POWER CIRCUIT SCREW TERMINALS 2 2.5-10 MMAFLEXIBLE WITH CABLE END
Type
Contactor
Voltage
690 Volt
Wattage
14 Watt 24 Volt DC-13 10000000 CYCLES - CONTROL CIRCUIT-48 Watt 24 Volt DC-13 3000000 CYCLES - CONTROL CIRCUIT-96 Watt 24 Volt DC-13 1000000 CYCLES - CONTROL CIRCUIT3.7 Watt AC-3 - 9.6 Watt AC-1

Manufacturer Information

Brand
Schneider Electric
Sub Brand
LC1D

General Product Info

12-Digit UPC
338911042087
GTiN
03389110420814
Product UPC
78590142081
Weight
2.185 kg

Dimensions

Depth
6.93 in
Height
5 in
Warranty Length
18 mth
Width
3.35 in

Certifications and Compliance

CA Prop65 Warning
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Certifications
BV,CCC,CSA,DNV,GL,GOST,RINA,UKCA,UL
Country of Origin
Czechia
Insulation Resistance
  • > 10 MOhm for control circuit
Connections Terminals
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid without cable end
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: ri
IE Rated Operational Current
  • 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
  • 80 A (at <60 °C) at <= 440 V AC AC
ITH Conventional Free Air Thermal Current
  • 80 A (at 60 °C) for power circuit
  • 10 A (at 60 °C) for control circuit
CAD
  • https://download.schneider-electric.com/files?p_Doc_Ref=LC1D50BD-CAD
  • https://download.schneider-electric.com/files?p_Doc_Ref=LC1D50BD_2D
IP Degree Of Protection
  • IP2X VDE 0106
  • IP2X IEC 60529
Climatic Withstand
  • IACS E10 exposure to damp heat
Power Dissipation Per Pole
  • 9.6 W AC-1
  • 3.7 W AC-3e
  • 3.7 W AC-3
Maximum Operating Rate
  • 3600 cyc/h at 60 °C
Prop 65
  • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Carbon Footprint Of The Installation Phase A5
  • 0.1 kg CO2 eq.
  • 0.0574439490046993
Non Overlap Time
  • 1.5 ms on energisation between NC and NO contacts
  • 1.5 ms on de-energisation between NC and NO contacts
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 3.822554669518983
  • 4 kg CO2 eq.
Standards
  • CSA C22.2 No 14
  • IEC 60947-5-1
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
Operating Time
  • 50 15 % ms closing
  • 20 20 % ms opening
Control Circuit Type
  • DC wide range
Minimum Switching Voltage
  • 17 V for control circuit
UC Control Circuit Voltage
  • 24 V DC
Related Products
  • with
  • LADN22
  • LADN11
  • LADN20
  • LADT2
  • LADN40
  • LADN31
  • LADN02
  • LADT0
  • LADS2
  • LADR2
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 13 kg CO2 eq.
  • 12.699016415047677
UI Rated Insulation Voltage
  • control circuit 600 V UL
  • power circuit 600 V CSA
  • power circuit 600 V UL IEC 60947-1
  • po
Rated Operational Power In W
  • 48 W 24 V DC-13 3000000 cycles - control circuit
  • 96 W 24 V
Maximum Horse Power Rating
  • 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
  • 15 hp at 200/2
Market Segmentation
  • Commercial
  • Industrial
Persona Type Names
  • End User
  • Contractor
  • Original Equipment Manufacturer
  • OEM - Control Panelbuilder
  • Panel Builder
  • System Integrator
Inrush Power In W
  • 19-19 W 20 °C)
Fire Resistance
  • 850 °C IEC 60695-2-1
Motor Power KW
  • 25 kW at 415 V AC 50 Hz (AC-3)
  • 30 kW at 440 V AC 50 Hz (AC-3)
  • 30 kW
Flame Retardance
  • V1 conforming to UL 94
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 80 kg CO2 eq.
  • 80.1695225555932
Persona Type Ids
  • EU
  • LC
  • OM
  • OM8
  • PB
  • SI
Auxiliaries
  • LADN22
  • LADN11
  • LADN20
  • LADT2
  • LADN40
  • LADN31
  • LADN02
  • LADT0
  • LADS2
  • LADR2
Safety Reliability Level
  • B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanica
Carbon Footprint Of The Distribution Phase A4
  • 2.727763222546913
  • 3 kg CO2 eq.
Tightening Torque
  • control circuit 1.7 N.m screw clamp terminal Philips No 2
  • power circuit 5 N.m sc
Mechanical Robustness
  • shocks contactor closed 15 Gn for 11 ms)
  • vibrations contactor opened 2 Gn, 5...300 Hz)
  • vibrations contactor opened 2 Gn, 5...3
Minimum Switching Current
  • 5 mA for control circuit
Control Circuit Voltage Limits
  • 0.75...1.25 Uc (-40-60 °C):operational DC
  • 1...1.25 Uc (60-70 °C):operational DC
  • 1...1.25 U
Hold In Power Consumption In W
  • 7.4-7.4 W 20 °C
Market Segmentation Id
  • COMMERCIAL
  • INDUSTRIAL
IRMS Rated Making Capacity
  • 900 A at 440 V DC for power circuit conforming to IEC 60947
  • 900 A at 440 V
Associated Fuse Rating
  • 100 A gG at <= 690 V coordination type 1 for power circuit
  • 100 A gG at <= 690
UE Rated Operational Voltage
  • power circuit <= 690 V AC 25...400 Hz
Rated Breaking Capacity
  • 900 A at 440 V for power circuit conforming to IEC 60947
UIMP Rated Impulse Withstand Voltage
  • 8 kV IEC 60947



Compare