NVENT HOF PSTD20612BM PROLINE Chim

Manufacturer: Hoffman | Catalog # PSTD20612BM | Cooper Electric Part # 2250616

$8,423.67 /ea
ea
Log in or register to view your price, purchase history, and more!
Out of stock, please contact your sales representative for availability, pricing and lead times
ProLine FloTek TD improves efficiency lowering energy costs by directing hot exhaust up the plenum. This ProLine FloTek TD (Top Duct) Server Cabinet BM, PSTD20612BM item measures 78.37x23.94x47.22in with a material of Steel colored Black.

Technical Information

Applications
PROLINE™ FLOTEK™ TD improves equipment efficiency and lowers energy costs by directing hot exhaust from the cabinet up above the plenum or drop ceiling and away from the cold room air. Photo shown with Tool-less (Snap-in) Blanking Panels installed. Order separately.
Color Coding
RAL 9005
Material
Steel
Type
PROLINE™ FLOTEK™ TD (Top Ducted) Server Cabinet

Manufacturer Information

Brand
nVent Hoffman
Sub Brand
Proline

General Product Info

12-Digit UPC
783510192747
Color
Black
Finish
Powder Coated
GTiN
00783510192747
Product UPC
78351019274
Weight
446 lb

Dimensions

Depth
47.22 Inch
Height
78.37 Inch
Length
85 Inch
Thickness
1.5 mm
Width
23.94 in
Features
  • Designed for use with 19-in. rack-mounted servers, blade servers and other equipment
  • Adjustable top duct (chimney) is provided in two different standard heights to fit various Data Center ceilings
  • Chimney is pre-assembled and shipped inside the cabinet to ease assembly and avoid extra parcels and shipping damage
  • S-connectors provided with chimney to facilitate connection to HVAC duct work
  • Edge gasket provided with chimney to prevent hot exhaust gas from mixing with cold airflow
  • Cabinet is provided with seals and blocking panels to eliminate cold air bypass
  • Includes two sets of fully adjustable mounting angles which are RU marked front and back to facilitate assembly
  • Open base allows under-floor cable entry
  • Fully perforated front door provides unrestricted cold airflow to equipment
  • Front sealed 19-in. mounting rails and top/bottom air blocking plates prevent cold air bypass
  • Solid rear door directs hot exhaust into chimney to prevent mixing with cold airflow
  • Data center efficiency increases when cold and hot airflows are kept separate resulting in higher CRAC temperatures (cold airflow to the equipment)
  • Reduces overall energy needs with more efficient cold air delivery to equipment
  • Allows increased thermal loads and higher server densities inside cabinet
  • Can be used on raised and non-raised floors
  • Top sliding gland plate accommodates cables, cable bundles and pre-terminated patch panels
  • Chimney provided with edge gasket and S-connectors
  • Attractive, rigid front door made of aluminum extrusions and formed perforated steel, with more than 60 percent open space for free flow of cool air to equipment
  • Front door is left-hinged and reversible
  • Front and rear doors have keyed multi-point vault-style latch system and central key lock to ensure security
  • Solid rear door is fully gasketed to ensure all hot exhaust is directed to top duct
  • Front air dam surrounds mounting rack angles to prevent cold air bypass
  • Top and sides are formed steel
  • Rack angles have .375-in. spaced square holes per EIA standards



Compare