Product image for SQD ATV650U15N4U Variable speed dri

Email

SQD ATV650U15N4U Variable speed dri

Manufacturer: Square-D / Schneider | Catalog # ATV650U15N4U | Cooper Electric Part # 1918625

$2,152.66 /ea
ea
Log in or register to view your price, purchase history, and more!
Out of stock, please contact your sales representative for availability, pricing and lead times
variable speed drive, Altivar Process ATV600, ATV650, 1.5kW, 400...480V, IP55

Technical Information

Connection Type
RJ45 On The Remote Graphic Terminal)Ethernet/Modbus TCP,RJ45 On The Remote Graphic Terminal)Modbus Serial
Mounting Type
Wall-Mounted
Net Weight
10.5 kg
Number of Phases
3 Phase
Standard
EN/IEC 61800-3 Environment 1 Category C2,EN/IEC 61800-3 Environment 2 Category C3,EN/IEC 61800-5-1,IEC 13849-1,IEC 60721-3,IEC 61000-3-12,IEC 61508,UL 508C
Storage Temperature
-40-70 degrees C

Manufacturer Information

Brand
Schneider Electric

General Product Info

12-Digit UPC
606480906995
GTiN
03606480906992
Product UPC
60648090699
Weight
10.5 kg

Dimensions

Depth
10.71 in
Height
26.69 in
Width
10.39 in

Certifications and Compliance

CA Prop65 Warning
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Certifications
ABS,ATEX INERIS,Bureau Veritas,CSA,DNV-GL,TV,UL
Country of Origin
China
Insulation Resistance
  • > 1 MOhm 500 V DC for 1 minute to earth
Environmental Class During Storage
  • class 1C3 according to EN 60721-3-1
  • class 1S2 according to EN 60721-3-1
Connector Type
  • RJ45 on the remote graphic terminal)Modbus serial
  • RJ45 on the remote graphic terminal)Ethernet/Modbus TCP
  • RJ45 on the remote graphic terminal)Ethernet/Mod
Exchange Mode
  • half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Analogue Input Type
  • AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits
  • AI1, AI2, AI3 software-configura
Continuous Output Current
  • 2.2 A 4 kHz heavy duty
  • 4 A 4 kHz normal duty
Prop 65
  • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Analogue Output Type
  • software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
  • software-configurable voltage AQ1, AQ2 0...10 V DC 47
Carbon Footprint Of The Installation Phase A5
  • 7 kg CO2 eq.
  • 7.322172232
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 2.9973163445
  • 3 kg CO2 eq.
Standards
  • environment 1 category C2 IEC 61800-3
  • environment 2 category C3 IEC 61800-3
  • IEC 61800-5-1
  • IEC 61000-3-12
  • IEC 60721-3
  • IEC 61508
  • IEC 13849-1
  • UL 508C
Ue Rated Operational Voltage
  • 380...480 V 1.5 kW 2 hp normal duty
  • 380...480 V 0.75 kW 1 hp heavy duty
  • 38
Ip Degree Of Protection
  • IP55IEC 60529
  • IP55IEC 61800-5-1
Discrete Input Type
  • DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
  • DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V
Electrical Connection
  • line side screw terminal 4...6 mm²
  • motor screw terminal 4...6 mm²
  • control removable screw terminals 0.5...1.5 mm² AWG 20..
Emc Filter
  • integrated 50 m IEC 61800-3 category C2
  • integrated 150 m IEC 61800-3 category C3
  • integrated 1
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 185 kg CO2 eq.
  • 184.9928383128
Maximum Thdi
  • <48 % full load IEC 61000-3-12
Method Of Access
  • slave Modbus TCP
Line Current
  • 2.6 A 480 V normal duty)
  • 1.7 A 380 V heavy duty)
  • 1.5 A 480 V heavy duty)
  • 3 A 380 V normal duty)
  • 3 A 380 V no
Motor Slip Compensation
  • adjustable
  • can be suppressed
  • not available in permanent magnet motor law
  • automatic whatever the load
Maximum Switching Current
  • relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC
  • relay output R1, R
Relay Output Type
  • configurable relay logic R2 sequence relay NO 100000 cycles
  • configurable r
Input Compatibility
  • DI5, DI6 discrete input level 1 PLC IEC 65A-68
  • STOA, STOB discrete input level 1 PLC IEC 61131-2
  • STOA, STOB discr
Frequency Resolution
  • analog input 0.012/50 Hz
  • display unit 0.1 Hz
Protection Type
  • safe torque off motor
  • motor phase break motor
  • thermal protection drive
  • safe torque off drive
  • overheating drive
  • overcurrent between output phase
Supply
  • internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection
  • internal
Permissible Temporary Current Boost
  • 1.5 x In 60 s heavy duty)
  • 1.1 x In 60 s normal duty)
Sampling Duration
  • 5 ms +/- 1 ms DI5, DI6) - discrete input
  • 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input
  • 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog inpu
Linearity Error
  • AO1, AO2 +/- 0.2 % analog output
  • AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
  • AI1, AI2, AI3 +/- 0.15 % of maximum value ana
Environmental Class During Operation
  • class 3C3 according to IEC 60721-3-3
  • class 3S3 according to IEC 60721-3-3
Maximum Horse Power Rating
  • 1 hp heavy duty
  • 2 hp normal duty
Communication Port Protocol
  • Modbus TCP
  • Ethernet
Vibration Resistance
  • 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6
  • 1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6
  • 1.5 mm peak to peak (f= 2-13 Hz) conforming to IE
Option Card
  • slot A communication module, PROFINET
  • slot A communication module, DeviceNet
  • slot A communication mo
Refresh Time
  • relay output R1, R2, R3)5 ms +/- 0.5 ms)
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 2 599 kg CO2 eq.
  • 2599.0736702371
Electromagnetic Compatibility
  • radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
  • radiated radio-frequency electromagnetic field immunity test
Supply Frequency
  • 50...60 Hz - 5...5 %
Apparent Power
  • 1.2 kVA 480 V heavy duty)
  • 2.2 kVA 480 V normal duty)
Relative Humidity
  • 5-95 % without condensation IEC 60068-2-3
Environmental Class During Transport
  • class 2C3 according to EN 60721-3-2
  • class 2S1 according to EN 60721-3-2
Number Of Addresses
  • 1-247 Modbus serial
Us Rated Supply Voltage
  • 380...480 V - 15...10 %
Carbon Footprint Of The Distribution Phase A4
  • 2.9332737258
  • 3 kg CO2 eq.
Synchronous Motor Control Profile
  • synchronous reluctance motor
  • permanent magnet motor
Minimum Switching Current
  • relay output R1, R2, R3 5 mA 24 V DC
Operating Altitude
  • 1000...4800 m with current derating 1 % per 100 m
  • <= 3280.84 ft (1000 m) without derating
Motor Power Kw
  • 0.75 kW heavy duty)
  • 1.5 kW normal duty)
Noise Level
  • 52 dB 86/188/EEC
Safety Function
  • STO (safe torque off) SIL 3
Discrete Input Logic
  • positive logic (source) DI1...DI8), < 5 V, > 11 V
  • negative logic (sink) DI1...DI8), > 16 V, < 10 V
  • negat
Asynchronous Motor Control Profile
  • constant torque standard
  • optimized torque mode
  • variable torque standard
Product Destination
  • asynchronous motors
  • synchronous motors
Discrete Output Type
  • relay outputs R1A, R1B, R1C 250 V AC 3000 mA
  • relay outputs R1A, R1B, R1C 3
Shock Resistance
  • 15 gn 11 ms IEC 60068-2-27
Maximum Transient Current
  • 3.3 A 60 s heavy duty)
  • 4.4 A 60 s normal duty)
Transmission Rate
  • 10, 100 Mbits
  • 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Local Signalling
  • 3 LEDs (dual colour) for embedded communication status
  • 4 LEDs (dual colour) for communication module status
  • 4 LEDs (dual colour) for communicati
Ambient Air Temperature For Operation
  • 40-50 °C (with derating factor)
  • -15-40 °C (without derating)
Product Certifications
  • UL
  • CSA
  • TV
  • DNV-GL
  • Bureau Veritas
  • ABS
  • ATEX INERIS
Switching Frequency
  • 4...12 kHz with derating factor
  • 2...12 kHz adjustable



Compare