This safety relay is designed for monitoring Emergency stop, Antivalent contacts, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch, Safety light curtain or Two-hand control stations. The safety relay is powered with 48-240V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 1 safety input, 2 ON/OFF configurable pulsed outputs, 1 single changeover safety output , and 1 solid state diagnostic output with complete status information. The maximum safety level achieved by this safety relay is PLc/Category 1 conforming to ISO 13849-1, SILCL 1 conforming to IEC 62061 and SIL 1 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, T.V, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.

Technical Information

Contact Configuration
1 C/O
Net Weight
0.200 kg
Number of Outputs
2 On/off Configurable Pulsed Output
Operating Temperature
-25-55 degrees C
Standard
IEC 60947-5-1,IEC 61508-1 Functional Safety Standard,IEC 61508-2 Functional Safety Standard,IEC 61508-3 Functional Safety Standard,IEC 61508-4 Functional Safety Standard,IEC 61508-5 Functional Safety Standard,IEC 61508-6 Functional Safety Standard,IEC 61508-7 Functional Safety Standard,IEC 62061 Functional Safety Standard,ISO 13849-1 Functional Safety Standard

Manufacturer Information

Brand
Schneider Electric

General Product Info

12-Digit UPC
606489601594
GTiN
03606489601591
Product UPC
60648960159
Weight
0.200 kg

Dimensions

Depth
4.72 in
Height
3.94 in
Width
0.89 in

Certifications and Compliance

CA Prop65 Warning
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Certifications
CULus,TV
Country of Origin
Indonesia
Power Consumption In W
  • 2.0 W 48 V DC
US Rated Supply Voltage
  • 48...240 V AC/DC - 10...10 %
Minimum Output Current
  • 10 mA relay output
Safety Reliability Data
  • MTTFd >= 30 years ISO 13849-1
  • Dcavg < 60 % ISO 13849-1
  • PFHd = 1177E-09 1/h ISO 13849-1
  • HFT = 0 IEC 62061
  • PFHd = 1177E-09 1/h IEC 62061
  • PFHd = 1177E-0
Connections Terminals
  • removable screw terminal block, 0.2...2.5 mm² solid or flexible
  • removable screw terminal block, 0.25...2.5 mm² flexible with f
Input Output Type
  • semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
  • semiconductor pulsed di
IE Rated Operational Current
  • 5 A AC-1 for normally open relay contact
  • 3 A AC-15 for normally open relay contact
  • 5 A D
IP Degree Of Protection
  • IP20 terminals)IEC 60529
  • IP40 housing)IEC 60529
  • IP54 mounting area)IEC 60529
Prop 65
  • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Carbon Footprint Of The Installation Phase A5
  • 0 kg CO2 eq.
  • 0.009367304866983317
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 0.5727557331507518
  • 0.6 kg CO2 eq.
Standards
  • IEC 60947-5-1
  • IEC 61508-1 functional safety standard
  • IEC 61508-2 functional safety standard
  • IEC 61508-3 functional safety standard
  • IEC 61
Safety Module Application
  • for electrical monitoring of two-hand control stations
  • for application with safety switchover contact
  • for emergency stop, guard and light curtain monitoring
  • monitoring antivalent contacts
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 5 kg CO2 eq.
  • 4.650673358309385
Input Compatibility
  • normally closed circuit ISO 14119
  • XC limit switch ISO 14119
  • mechanical contact ISO 14119
  • normally closed circuit ISO 13850
  • antivale
UI Rated Insulation Voltage
  • 250 V 2)IEC 60947-1
Accessories
  • XPSES
  • XPSEC
Safety Level
  • can reach PL = c ISO 13849-1
  • can reach SILCL 1 IEC 62061
  • can reach SIL 1 IEC 61508
Persona Type Names
  • End User
  • Original Equipment Manufacturer
  • OEM - Control Panelbuilder
Power Consumption In VA
  • 6.5 VA 240 V AC 50/60 Hz
Number Of Inputs
  • 1 safety input 24 V DC 5
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 65 kg CO2 eq.
  • 64.56882742021409
Number Of Outputs
  • 2 on/off configurable pulsed output
Relative Humidity
  • 5-95 % non-condensing
Accessory Products
  • XPSES
  • XPSEC
Persona Type Ids
  • EU
  • OM
  • OM8
Minimum Output Voltage
  • 15 V relay output
Carbon Footprint Of The Distribution Phase A4
  • 0.12159391800643612
  • 0.1 kg CO2 eq.
Associated Fuse Rating
  • 6 A gG relay output IEC 60947-1
Local Signalling
  • LED (green) for power ON
  • LED (red) for error
  • LED (yellow) for start
  • LED (yellow) for safety status
  • LED (yellow) for sa
UIMP Rated Impulse Withstand Voltage
  • 4 kV II IEC 60947-1



Compare