Product image for LEV OSSMD-GAW DUAL RLY MT WB, 120-2
Image thumbnail 0
Image thumbnail 1
Image thumbnail 2
Image thumbnail 3

Email

LEV OSSMD-GAW DUAL RLY MT WB, 120-2

Manufacturer: Leviton Mfg Co | Catalog # OSSMD-GAW | Cooper Electric Part # 1735714

$210.00 /ea
ea
Log in or register to view your price, purchase history, and more!
Out of stock, please contact your sales representative for availability, pricing and lead times
Product Line: OSSMD, Technology: Multi-Technology PIR/Ultrasonic, Switch Type: Single-Pole, Dual Relay, Mounting: Wall Switch, Device Type: Occupancy Sensor, Coverage (Sq.Ft.): 2400 Sq. Ft., Voltage: 120-277 Volt AC, 50/60Hz, Pattern: 180., Color: White, Neutral Wire Connection: Not Required, Domestic Content: Made in USA with globally sourced components, Warranty: 5-Year Limited

Technical Information

Applications
Commercial
Coverage
2400 sq-ft
Device Type
Occupancy Sensor
Frequency
50 Hz
Grade
Commercial
LED Color
Green,Red
Mounting Type
Wall Switch
Operating Temperature
0 degrees
Power Consumption
120 V
Sensor Type
Wall Switch
Size
1.35 in
Standard
CEC Title 24 Compliant,CSA,ETL\C-ETL Listed,FCC Compliant,NAFTA (CF434),NOM
Storage Temperature
-10 To 85 degrees C
Switch Type
Dual Relay,Dual Relay,Single-Pole,Single-Pole
Type
Dual Relay,Occupancy Sensor,Single-Pole Switch
Voltage
120 Volt

Manufacturer Information

Brand
Leviton
Sub Brand
OCC SENSOR WALLPLATE

General Product Info

12-Digit UPC
078477509074
Color
White
Environmental Conditions
Humidity (20 To 90 Non-Condensing) %
GTiN
00078477509074
Product UPC
07847750907

Dimensions

Warranty Length
5 yr

Certifications and Compliance

Certifications
ETL/C-ETL
Country of Origin
USA
Made In USA
Yes
Features
  • Provides automatic lighting control for two separate banks of fluorescent, incandescent, or low-voltage lighting from a single unit.
  • The second relay is a manual-ON only with a maximum 30 minute time-out for maximum energy savings to comply with CEC Title 24.
  • Fits in a standard single-gang wall box and replaces two single-pole wall-switches for fast and easy installation; neutral and ground connection required for OSSMD-MD. OSSMD-GD does not require a neutral for installation.
  • Low-profile design eliminates obtrusive scanning-device look. Elegant Decora wallplates complement any interior for sleek aesthetics; uses Decora wallplates and coordinates with Levitons popular line of Decora wiring devices.
  • 180° field-of-view provides approximately 2400 square feet of coverage, suitable for a variety of commercial areas.
  • Convenient pushbuttons provide manual-ON/OFF light switching of each load at any time.
  • Segmented Fresnel lens provides optimum sensitivity and performance. Designed with an extensive minor motion area where even slight body movements will be detected.
  • Vandal resistant PIR lens.
  • Adjustable horizontal field-of-view (PIR) may be adjusted between 180° and 60° of arc by using integral blinders located on either side of the lens. No masking tape required.
  • Manual-ON/auto-OFF mode for installations where manual-ON switching is required but auto-OFF switching is still desired for CEC Title 24 energy savings.
  • To comply with CEC Title 24, LED indicator light flashes when sensor detects motion to verify detection is active. Green flashes for ultrasonic, red flashes for PIR.
  • Time delay adjustment for delayed-OFF time settings of 30 seconds (for walking test), 10 minutes, 20 minutes, and 30 minutes. Allows customized adjustments to maximize energy savings.
  • Light sensor measures the ambient light in the room when it first detects motion and leaves the lights OFF (hold-off) if there is enough light in the room or turns the lights connected to the first relay ON if there is not enough light in the room.
  • Self-Adaptive technology eliminates callbacks for adjustments. Time delay and sensitivity settings are continually adjusted to occupant patterns of use in auto adapt mode.
  • Exclusive Walk-Through feature provides increased energy savings by not leaving the lights ON for an extended period after only momentary occupancy.
  • Non-Adaptive Mode disables self-adjusting delayed-OFF time and walk-through feature in applica-tions where these feature are not desired. Optional manual adjustment for delayed-OFF time settings allows customized adjustments to maximize energy savings.
  • Vacancy confirmation; when the time out expires and the relay turns OFF, a 30-second vacancy confirmation exists to turn the relays back ON.
  • False detection circuitry.
  • U/S technology provides excellent minor motion sensitivity.
  • Ability to disable PIR or U/S for added flexibility.
  • Presentation Mode feature for slide or film presentations allows pushbuttons to turn lights OFF and keep them OFF while the room is occupied.
  • Exclusive Leviton High Inrush Stability (H.I.S.) Circuitry. Specifically designed to handle todays high inrush electronic ballast loads and offer unmatched durability and service.
  • One unit can be used for 120V through 277V lighting. Compatible with both electronic and magnetic ballasts.
  • True zero-cross relay switches at the zero crossing point of the AC power curve to ensure maximum contactor life and compatibility with electronic ballasts.
  • OSSMD dual relay occupancy sensors combine Passive Infrared (PIR) and Ultrasonic (U/S) motion detection technologies in a single sensor to keep lights ON while a space is occupied and turn lights OFF when vacant. Do you have a question about an occupancy sensor or vacancy sensor?
Patents
  • US8115626
Color Variations
  • Black
Related Products
  • OSSMD-GAE
  • OSSMD-GAG
  • OSSMD-GAI
  • OSSMD-GAT



Compare