VCCF2 is a 3-pole TeSys Vario switch-disconnector from Schneider Electric. Rated 40A 690V, it is used for main and emergency stop switching in motor applications up to 15kW@400V AC-23. Composed of a V2 switch body, extension shaft, red padlockable handle, and a yellow 60x60mm front plate. For enclosure back mounting, with a 4 screw fixing handle, it ensures IP65 to the mounting. Available worldwide, multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs/Reach). Possible distance between back of enclosure and door 300-330mm. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Technical Information

Actuator
RED,ROTARY HANDLE
Amperage
29 Amp AC-23 UE: 400 V
Applications
MAIN SWITCH DISCONNECTOR
Contact Configuration
3 NO
Control Type
Rotary handle
Enclosure
IP65-IP20 CONFORMING TO IEC 60529
Interrupt Rating
320 AIC
Net Weight
0.527 kg
Number of Poles
3 Pole
Operating Cycles
30000 CYCLES DC-1...5-100000 CYCLES AC-21
Operating Temperature
-4122 degrees F (-2050 degrees C)
Range
TeSys
Size
60 MM,60 X 60 MM,74 MM
Standard
IEC 60947-3
TC Connection
POWER CIRCUIT SCREW CLAMP TERMINALS 10-10 MMA SOLID-POWER CIRCUIT SCREW CLAMP TERMINALS 6-6 MMA FLEXIBLE - WITH CABLE END
Type
EMERGENCY STOP SWITCH DISCONNECTOR
Voltage
690 Volt
Wattage
11 kW 690 Volt AC-3)-15 kW 690 Volt AC-23 Amps)-11 kW 400...415 Volt AC-3)-15 kW 500 Volt AC-3)-18.5 kW 500 Volt AC-23 Amps)-5.5 kW 230...240 Volt AC-3)-7.5 kW 230...240 Volt AC-23 Amps)-15 kW 400...415 Volt AC-23 Amps)

Manufacturer Information

Brand
Schneider Electric
Sub Brand
TESYS VARIO,VCCF

General Product Info

12-Digit UPC
338911044937
Environmental Conditions
OPEN
GTiN
03389110449327
Handle Color
Red
Product UPC
78590144932
Weight
0.527 kg

Dimensions

Height
2.91 in
Warranty Length
18 mth
Width
2.36 in

Certifications and Compliance

CA Prop65 Warning
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Certifications
CCC,CSA,GL,UKCA,UL
Country of Origin
Czechia
Connections Terminals
  • power circuit screw clamp terminals 10-10 mm² solid
  • power circuit screw clamp terminals 6-6 mm² flexible - with cable end
IE Rated Operational Current
  • 29 A AC-23 Ue: 400 V
Mounting Support
  • handle door
  • switch symmetrical rail
  • switch plate
CAD
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_3D-simplified.stp
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-back.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-back.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-bottom.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-bottom.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-front.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-front.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-isometric.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-isometric.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-left.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-left.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-right.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-right.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-top.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADPD0005317_3D-CAD&p_File_name=MCADPD0005317_2D-top.dxf
IP Degree Of Protection
  • IP20 conforming to IEC 60529
  • IP65
Making Capacity
  • 400 A 400 V AC-21A
  • 400 A 400 V AC-22A
  • 400 A 400 V AC-23A
Prop 65
  • WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Carbon Footprint Of The Installation Phase A5
  • 0.04620602656650971
  • 0 kg CO2 eq.
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 1 kg CO2 eq.
  • 1.397521947531439
ICW Rated Short Time Withstand Current
  • 480 A 400 V 1 s
Related Products
  • VZ11
  • VZ7
  • VZ14
  • VZ20
  • VZ2
ICM Rated Short Circuit Making Capacity
  • 1 kA 400 V at Ipeak
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 3 kg CO2 eq.
  • 3.3289718359735767
Rated Operational Power In W
  • 11 kW 690 V AC-3)
  • 15 kW 690 V AC-23A)
  • 11 kW 400...415 V AC-3)
  • 15 kW 500 V AC-3)
  • 18.5 kW 500 V AC-23A)
  • 5.5 kW 230...240 V AC-3)
  • 7.5 kW 230...240 V AC-23A)
  • 15 kW 400...415 V AC-23A)
Electrical Durability
  • 100000 cycles AC-21
  • 30000 cycles DC-1...5
Fixing Mode
  • by 4 screws handle
  • by clips switch
  • by screws switch
Fire Resistance
  • 960 °C IEC 60695-2-1
Add Ons
  • VZ11
  • VZ7
  • VZ14
  • VZ20
  • VZ2
Rotary Handle Padlocking
  • 1 to 3 padlocks 4-8 mm
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 29 kg CO2 eq.
  • 28.971796700100345
Accessory Products
  • VZ8
Carbon Footprint Of The Distribution Phase A4
  • 0.1026947865916101
  • 0.1 kg CO2 eq.
Tightening Torque
  • power circuit 2.1-2.1 N.m screw clamp terminals
Mechanical Robustness
  • vibrations 10...150 Hz 1 gn) IEC 60068-2-6
  • shocks 11 ms 30 Gn) IEC 60068-2-27
Network Type
  • AC
  • DC
UE Rated Operational Voltage
  • 690 V AC 50/60 Hz
Rated Conditional Short Circuit Current
  • 10 kA 400 V 50 A aM
  • 10 kA 400 V 50 A gG