Product image for SQD TM3TM3G analog IO module, Modic
Image thumbnail 0
Image thumbnail 1
Image thumbnail 2

Email

SQD TM3TM3G analog IO module, Modic

Manufacturer: Square-D / Schneider | Catalog # TM3TM3G | Cooper Electric Part # 1438115

$380.23 /ea
ea
Log in or register to view your price, purchase history, and more!
Out of stock, please contact your sales representative for availability, pricing and lead times
This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The analogue I/O module provides 2 inputs, 1 output with 16bit, 15bit + sign input resolution. It is an I/O module with a rated supply

Technical Information

Applications
MODICON TM3
Current
24 V
Impedance
50 ohm
Load Type
Resistive
Net Weight
0.1 kg
Size
23.6 MM,70 MM,90 MM
Standard
IEC 61131-2
Storage Temperature
-25-70 degrees C
TC Connection
11 X 2.5 MMA REMOVABLE SPRING TERMINAL BLOCK PITCH 5.08 MM FOR INPUTS, OUTPUTS AND SUPPLY
Type
INPUT/OUTPUT ANALOG MODULE

Manufacturer Information

Brand
Schneider Electric

General Product Info

12-Digit UPC
606480649052
GTiN
03606480649059
Product UPC
78590198599
Weight
0.1 kg

Dimensions

Depth
2.76 in
Height
3.54 in
Width
0.93 in

Certifications and Compliance

CA Prop65 Warning
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Certifications
CE,CULus,CULus HazLoc,EAC,RCM,UKCA
Country of Origin
Japan
US Rated Supply Voltage
  • 24 V DC
Current Consumption
  • 55 mA 24 V DC via external supply no load
  • 55 mA 5 V DC via bus connector no load
  • 55 mA
Mounting Support
  • top hat type TH35-15 rail IEC 60715
  • top hat type TH35-7.5 rail IEC 60715
  • plate or panel with fixing kit
Resistance To Magnetic Fields
  • 30 A/m IEC 61000-4-8
Analogue Input Type
  • current 4...20 mA
  • current 0...20 mA
  • voltage 0...10 V
  • voltage - 10...10 V
  • thermocouple - 200...1000 °C thermocouple J
  • thermocouple - 200..
Prop 65
  • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Analogue Output Type
  • current 4...20 mA
  • current 0...20 mA
  • voltage 0...10 V
  • voltage - 10...10 V
Permissible Continuous Overload
  • 13 V voltage
  • 40 mA current
Carbon Footprint Of The Installation Phase A5
  • 0 kg CO2 eq.
  • 0.005268691234095478
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 0.4783742797729333
  • 0.5 kg CO2 eq.
Resistance To Conducted Disturbances
  • 10 V 0.15...80 MHz IEC 61000-4-6
  • 3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
  • 3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 1
LSB Value
  • 0.15 mV 0...10 V voltage
  • 0.30 mV - 10...10 V voltage
  • 0.30 A 0...20 mA current
  • 0.244 A 4...20 m
Electrical Connection
  • 11 x 2.5 mm² removable spring terminal block with pitch 5.08 mm adjustment for inputs, outputs and supply
  • 11 x 2.5 mm² removable spring terminal blo
Related Products
  • ESEEXPCZZSPAZZ
  • ESECAPCZZSPAZZ
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 13 kg CO2 eq.
  • 12.926781354982458
Sampling Duration
  • 10 ms voltage/current
  • 100 ms voltage/current
  • 100 ms thermocouple
  • 100 ms temperature probe
Vibration Resistance
  • 3.5 mm 5-8.4 Hz DIN rail
  • 3 gn 8.4-150 Hz DIN rail
Persona Type Names
  • End User
  • Original Equipment Manufacturer
  • OEM - Control Panelbuilder
Type Of Cable
  • twisted shielded pairs cable <30 m input/output
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 84 kg CO2 eq.
  • 84.24018131089299
Resistance To Fast Transients
  • 1 kV IEC 61000-4-4 I/O)
Conversion Time
  • 100 ms + 100 ms per channel + 1 controller cycle time thermocouple
  • 100 ms + 100 ms per channel + 1 controller cycle time temperature probe
  • 100 ms + 100 ms per channel + 1 controller cycle
Relative Humidity
  • 10-95 %, without condensation in operation)
  • 10-95 %, without condensation in storage)
  • 10-95 %, without condensation in stora
Accessory Products
  • TMAM2
Persona Type Ids
  • EU
  • OM
  • OM8
Surge Withstand
  • 1 kV power supply common mode IEC 61000-4-5
  • 0.5 kV power supply differential mode IEC 61000-4-5
  • 0.5 kV power supply differ
Electromagnetic Emission
  • radiated emissions 40 dB?V/m QP class A 10 m)30-230 MHz IEC 55011
  • radiated emissions 40 dB?V/m QP class A 10 m)30-230 MHz
Resistance To Electrostatic Discharge
  • 8 kV in air IEC 61000-4-2
  • 4 kV on contact IEC 61000-4-2
Carbon Footprint Of The Distribution Phase A4
  • 0.04467647430585781
  • 0 kg CO2 eq.
Insulation
  • between input and supply 1500 V AC
  • between input and internal logic 500 V AC
  • between output and supp
Analogue Input Resolution
  • 16 bits
  • 15 bits + sign
Repeat Accuracy
  • +/-0.5 %FS input
  • +/- 0.4 %FS output
Non Linearity
  • +/- 0.01 %FS analog output
  • +/- 0.1 %FS analog input
Resistance To Electromagnetic Fields
  • 10 V/m 80 MHz...1 GHz IEC 61000-4-3
  • 3 V/m 1.4 GHz...2 GHz IEC 61000-4-3
  • 1 V/m 2 GHz...3 GHz IEC 61000-4-3
  • 1 V/
Shock Resistance
  • 15 gn 11 ms
Load Impedance Ohmic
  • 1 kOhm voltage
  • 300 Ohm current
Input Impedance
  • <= 50 Ohm current
  • >= 1 MOhm voltage
  • >= 1 MOhm thermocouple
  • >= 1 MOhm temperature probe
Local Signalling
  • 1 LED (green) for PWR
Ambient Air Temperature For Operation
  • -10-55 °C horizontal installation
  • -10-35 °C vertical installation



Compare