Image thumbnail 1
Image thumbnail 2
Image thumbnail 3
Image thumbnail 4

Email

SQUARED XACA2813 Pendant control st

Manufacturer: Square-D / Schneider | Catalog # XACA2813 | Cooper Electric Part # 1394916

$338.10 /ea
ea
Log in or register to view your price, purchase history, and more!
Out of stock, please contact your sales representative for availability, pricing and lead times
This Schneider Electric Harmony XAC yellow pendant station for hoist motor has single speed. It has 1 "raise" + 1 "lower" + 1 emergency stop push-buttons and uses screw-clamp terminals. This pendant station for hoist motor is designed for standard or medium-duty control circuit applications in your machines. It has 2 push-buttons and 1 emergency stop with "raise" and "lower" markings, with normally open and normally close contact. It is impact resistant (strength), dust resistant (strength), water resistant (strength) and vibration resistant (strength) thanks to its IP65, making it ideal for operation in harsh (heavy) environments. Impact- and stain resistant (strength) enclosure for a sustained appearance despite rough usage conditions. No need to damage your machine or system with multiple 22mm hole, thus avoiding common issues like edge corrosion. Yellow enclosure, favoring visual contrast and visibility in dark conditions. Wide range of operating temperatures from -25.C to 70.C allows versatility in usage of product. Vibration resistant screw clamp connection terminals ensure high vibration resistance making product suitable installation on high impact machine.

Technical Information

Applications
ZB2BE102 FOR EMERGENCY STOP-ZB2BE102 + ZB2BE101 FOR EACH DIRECTION,CONTROL CIRCUIT,CONTROL OF SINGLE SPEED HOIST MOTOR
Cable Entry
8-26 mm
Contact Rating
SLOW-BREAK
Enclosure
POLYPROPYLENE
Enclosure Material
Polypropylene
Enclosure Type
Complete Ready For Use
Net Weight
0.6 kg
Operating Force
13-13 N
Operating Temperature
-25-70 Adegrees C
Standard
CSA C22.2 No 14,IEC 60204-32,IEC 60947-5-1,UL 508
Storage Temperature
-40-70 degrees C
TC Connection
SCREW CLAMP TERMINALS, 1 X 0.5...1 X 2.5 MMA WITHOUT CABLE END-SCREW CLAMP TERMINALS, 1 X 0.5...2 X 1.5 MMA WITH CABLE END
Type
DOUBLE INSULATED,PENDANT CONTROL STATION
Wattage
40 Watt DC-13 1000000 CYCLES 60 CYC/MN 120 Volt 0.5 INDUCTIVE IEC 60947 - 5-1 APPENDIX C-48 Watt DC-13 1000000 CYCLES 60 CYC/MN 48 Volt 0.5 INDUCTIVE IEC 60947 - 5-1 APPENDIX C-65 Watt DC-13 1000000 CYCLES 60 CYC/MN 24 Volt 0.5 INDUCTIVE IEC 60947 - 5-1 APPENDIX C

Manufacturer Information

Brand
Schneider Electric
Sub Brand
XACA

General Product Info

12-Digit UPC
389110426819
GTiN
03389110426816
Product UPC
38911042681
Weight
0.6 kg

Dimensions

Warranty Length
18 mth

Certifications and Compliance

CA Prop65 Warning
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Certifications
CCC,GOST
Country of Origin
Czechia
Connections Terminals
  • screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end
  • screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end
Overvoltage Category
  • class II conforming to IEC 61140
IP Degree Of Protection
  • IP65 conforming to IEC 60529
Prop 65
  • WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Control Button Type
  • stop push-button Ø 30 mm 1 NC latching
  • first push-button 1 NC + 1 NO raise, slow
  • second push-button 1 NC + 1 NO lower, slow
Carbon Footprint Of The Installation Phase A5
  • 0.0032016213
  • 0 kg CO2 eq.
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 0.6 kg CO2 eq.
  • 0.5800601399
Cable Entry
  • rubber sleeve with stepped entry 8-26 mm
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 3 kg CO2 eq.
  • 3.1797089355
UI Rated Insulation Voltage
  • 600 V 3)
Rated Operational Power In W
  • 40 W DC-13 1000000 cycles 60 cyc/mn 120 V 0.5 inductive IEC 60947-5-1 appendix C
  • 48 W DC-13 1000000 cycles 60 cyc/mn 48 V 0.5 inductive IEC 60947-5-1 appendix C
  • 65 W DC-13 1000000 cycles 60 cyc/mn 24 V 0.5 inductive IEC 60947-5-1 appendix C
Operating Force
  • 13-13 N push-button
  • 8-8 N emergency stop
Vibration Resistance
  • 15 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
Market Segmentation
  • Commercial
  • Industrial
Terminal Identifier
  • (11-12)NC
  • (13-14)NO
Persona Type Names
  • Charge Point Operator
  • End User
  • Contractor
  • Original Equipment Manufacturer
  • OEM - Control Panelbuilder
  • Panel Builder
  • Electrician
  • System Integrator
  • IT Channel Partner
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 0 kg CO2 eq.
  • 0
Persona Type Ids
  • BM9
  • EU
  • LC
  • OM
  • OM8
  • PB
  • SC
  • SI
  • VR
Terminals Description ISO N 1
  • (11-12)NC
  • (13-14)NO
Carbon Footprint Of The Distribution Phase A4
  • 0.1343391919
  • 0.1 kg CO2 eq.
Short Circuit Protection
  • 10 A fuse protection cartridge gG
Contact Code Designation
  • A600 AC-15, Ue = 240 V, Ie = 3 A IEC 60947-5-1 appendix A
  • A600 AC-15, Ue = 600 V, Ie = 1.2 A IEC 60947-5-1 appendix A
  • Q600 DC-13, Ue = 250 V, Ie = 0.27 A IEC 60947-5-1 appendix A
  • Q600 DC-13, Ue = 600 V, Ie = 0.1 A IEC 60947-5-1 appendix A
Market Segmentation Id
  • COMMERCIAL
  • INDUSTRIAL
Shock Resistance
  • 100 gn IEC 60068-2-27
Product Compatibility
  • ZB2BE102 for emergency stop
  • ZB2BE102 + ZB2BE101 for each direction
UIMP Rated Impulse Withstand Voltage
  • 6 kV IEC 60947-1



Compare