Image thumbnail 1
Image thumbnail 2
Image thumbnail 3
Image thumbnail 4

Email

SQD RM22TA33 3-phase control relay,

Manufacturer: Square-D / Schneider | Catalog # RM22TA33 | Cooper Electric Part # 1323015

*Call For Price*
Log in or register to view your price, purchase history, and more!
Out of stock, please contact your sales representative for availability, pricing and lead times
This Harmony RM22TA asymmetry control relay allows monitoring of power supply circuits in 3-phase networks. This modular 3-phase control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0

Technical Information

Contact Configuration
2 C/O
Contact Material
Cadmium Free
Line Rated Current
8 A
Net Weight
0.09 kg
Number of Phases
3 Phase
Size
0.89 in
Standard
IEC 60255-1
Storage Temperature
-40-70 degrees C
Type
3-phase control relay;Control relay

Manufacturer Information

Brand
Schneider Electric

General Product Info

12-Digit UPC
360648079210
GTiN
03606480792151
Housing Material
Plastic
Product UPC
78590169431
Weight
0.09 kg

Dimensions

Width
0.89 in

Certifications and Compliance

CA Prop65 Warning
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Certifications
CCC,CE,CSA,EAC,GL,RCM,UL
Country of Origin
Indonesia
Insulation Resistance
  • > 100 MOhm 500 V DC IEC 60255-27
US Rated Supply Voltage
  • AC/DC
  • , self-powered
Connections Terminals
  • screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
  • screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
  • screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
Overvoltage Category
  • III conforming to IEC 60664-1
  • III conforming to UL 508
Mounting Support
  • 35 mm DIN rail conforming to IEC 60715
CAD
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-back.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-back.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-bottom.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-bottom.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-front.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-front.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-isometric.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-isometric.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-left.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-left.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-right.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-right.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-top.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23_2D-top.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33_3DCAD&p_File_name=RM22TU23.STEP
  • https://download.schneider-electric.com/files?p_Doc_Ref=RM22TA33-3d
Supply Voltage Limits
  • 304-576 V AC
IP Degree Of Protection
  • IP20 IEC 60529 terminals)
  • IP40 IEC 60529 housing)
  • IP50 IEC 60529 front panel)
Prop 65
  • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Carbon Footprint Of The Installation Phase A5
  • 0 kg CO2 eq.
  • 0.0004490264
Voltage Range
  • 380...480 V phase to phase
Switching Threshold Drift
  • <= 0.05 % per degree centigrade depending permissible ambient air temperature
  • <= 1 % within the supply voltage range
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 0.0522965455
  • 0.1 kg CO2 eq.
Voltage Detection Threshold
  • < 100 V AC
Status Led
  • LED (Yellow) relay ON
  • LED (Green) power ON
Maximum Switching Voltage
  • 250 V AC
Dielectric Test Voltage
  • 2.5 kV AC 50 Hz, 1 min IEC 60255-27
Maximum Measuring Cycle
  • 150 ms measurement cycle as true rms value
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 2 kg CO2 eq.
  • 1.8499090909
Maximum Switching Current
  • 8 A AC
Time Delay Drift
  • <= 0.05 % per degree centigrade depending permissible ambient air temperature
  • <= 1 % within the supply voltage range
Time Delay Type
  • adjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault
Measurement Range
  • 380...480 V voltage AC
Reset Time
  • 1500 ms at maximum voltage
Vibration Resistance
  • 0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6
  • 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6
  • 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6
  • 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
Market Segmentation
  • Commercial
  • Industrial
Persona Type Names
  • Charge Point Operator
  • End User
  • Contractor
  • Original Equipment Manufacturer
  • OEM - Control Panelbuilder
  • Panel Builder
  • Electrician
  • System Integrator
  • IT Channel Partner
Measurement Error
  • < 1 % over the whole range with voltage variation
  • < 0.05 %/°C with temperature variation
Power Consumption In VA
  • 15-15 VA 480 V AC 60 Hz
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 93 kg CO2 eq.
  • 92.70576
Electromagnetic Compatibility
  • immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1
  • immunity for industrial environments conforming to IEC 61000-6-2
  • emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
  • emission standard for industrial environments conforming to IEC 61000-6-4
  • electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
  • electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
  • radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
  • electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4
  • electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4
  • surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
  • surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
  • conducted and radiated emissions class B group 1 conforming to CISPR 11
  • conducted and radiated emissions class B conforming to CISPR 22
Supply Frequency
  • 50...60 Hz +/- 10 %
Hysteresis
  • 2-2 % fixed selectable
Relative Humidity
  • 93-97 % 25-55 °C IEC 60068-2-30
Persona Type Ids
  • BM9
  • EU
  • LC
  • OM
  • OM8
  • PB
  • SC
  • SI
  • VR
Relay Monitored Parameters
  • phase sequence
  • phase failure detection
  • asymmetry
Carbon Footprint Of The Distribution Phase A4
  • 0.0116116364
  • 0 kg CO2 eq.
Tightening Torque
  • 0.6-1 N.m IEC 60947-1
Minimum Switching Current
  • 10 mA 5 V DC
Repeat Accuracy
  • +/- 0.5 % input and measurement circuit
  • +/- 3 % time delay
Utilisation Category
  • AC-15 IEC 60947-5-1
  • DC-13 IEC 60947-5-1
  • AC-1 IEC 60947-4-1
  • DC-1 IEC 60947-4-1
Market Segmentation Id
  • COMMERCIAL
  • INDUSTRIAL
Shock Resistance
  • 15 gn 11 ms) not in operation IEC 60068-2-27
  • 5 gn 11 ms) in operation IEC 60068-2-27
Ambient Air Temperature For Operation
  • -20-50 °C 60 Hz
  • -20-60 °C 50 Hz AC/DC



Compare