This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 4kW/5hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 3kW for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 380V to 480V AC. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments, oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures. It is designed to be mounted in vertical position (+/- 10 .) on a wall.

Technical Information

Applications
Industrial Application;Synchronous motors;Asynchronous motors
Connection Type
1 RJ45,2 RJ45
Mounting Type
Wall-Mounted
Net Weight
4.6 kg
Number of Phases
3 Phase
Output Voltage
<= power supply voltage
Size
8.11 in
Standard
IEC 13849-1,IEC 60721-3,IEC 61000-3-12,IEC 61508,IEC 61800-3,IEC 61800-5-1,UL 508C
Storage Temperature
-40-70 degrees C
Type
Variable speed drive

Manufacturer Information

Brand
Schneider Electric
Sub Brand
ALTIVAR PROCESS ATV900

General Product Info

12-Digit UPC
360648088328
Environmental Conditions
-15-50 A?C WITHOUT)-50-60 A?C WITH DERATING FACTOR),CHEMICAL POLLUTION RESISTANCE CLASS 3C3 EN/IEC 60721-3-3-DUST POLLUTION RESISTANCE CLASS 3S3 EN/IEC 60721-3-3
GTiN
03606480883293
Product UPC
78590147673
Weight
4.6 kg

Dimensions

Depth
8.11 in
Height
13.78 in
Width
5.67 in

Certifications and Compliance

CA Prop65 Warning
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Certifications
CSA,TV,UL
Country of Origin
Indonesia
Environmental Class During Storage
  • class 1C3 according to EN 60721-3-1
  • class 1S2 according to EN 60721-3-1
US Rated Supply Voltage
  • 380...480 V - 15...10 %
Exchange Mode
  • half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
CAD
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_3D-simplified.stp
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-back.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-back.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-bottom.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-bottom.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-front.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-front.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-isometric.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-isometric.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-left.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-left.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-right.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-right.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-top.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=MCADID0001058_3D-CAD&p_File_name=MCADID0001058_2D-top.dxf
  • https://download.schneider-electric.com/files?p_Doc_Ref=ATV930U40N4_2D&p_File_name=ATV930U40N4_2D.dwg
  • https://download.schneider-electric.com/files?p_Doc_Ref=ATV930U40N4_2D&p_File_name=ATV930U40N4_2D.dxf
Type Of Polarization
  • no impedance Modbus serial
Analogue Input Type
  • AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits
  • AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Continuous Output Current
  • 9.3 A 4 kHz normal duty
  • 7.2 A 4 kHz heavy duty
Prop 65
  • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Analogue Output Type
  • software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
  • software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Carbon Footprint Of The Installation Phase A5
  • 0.1 kg CO2 eq.
  • 0.0809387949
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 1.9506689862
  • 2 kg CO2 eq.
Encoder Protocol
  • 1 Vpp
  • EnDat 2.2
  • resolver
  • RS 422
  • SSI 24V
  • SSI 5V
  • TTL/HTL
Discrete Input Type
  • DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm
  • DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
  • STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
Related Products
  • VW3A1112
  • VW3A3721
  • VW3A3203
  • VW3A3204
  • VW3A3627
  • VW3A7750
  • VW3A3608
  • VW3A3618
  • VW3A3628
  • VW3A3607
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 83 kg CO2 eq.
  • 83.4085086193
Method Of Access
  • slave Modbus TCP
Line Current
  • 7.6 A 380 V normal duty)
  • 6.0 A 380 V heavy duty)
  • 6.7 A 480 V normal duty)
  • 5.4 A 480 V heavy duty)
Motor Slip Compensation
  • not available in permanent magnet motor law
  • can be suppressed
  • adjustable
  • automatic whatever the load
Variant
  • standard version
  • with braking chopper
Maximum Switching Current
  • relay output R1 resistive, cos phi = 1 3 A 250 V AC
  • relay output R1 resistive, cos phi = 1 3 A 30 V DC
  • relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
  • relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
  • relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC
  • relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC
  • relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC
  • relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay Output Type
  • configurable relay logic R1 fault relay NO/NC 100000 cycles
  • configurable relay logic R2 sequence relay NO 1000000 cycles
  • configurable relay logic R3 sequence relay NO 1000000 cycles
Input Compatibility
  • DI1...DI8 discrete input level 1 PLC IEC 61131-2
  • DI7, DI8 pulse input level 1 PLC IEC 65A-68
  • STOA, STOB discrete input level 1 PLC IEC 61131-2
Protection Type
  • thermal protection motor
  • safe torque off motor
  • motor phase break motor
  • thermal protection drive
  • safe torque off drive
  • overheating drive
  • overcurrent between output phases and earth drive
  • overload of output voltage drive
  • short-circuit protection drive
  • motor phase break drive
  • overvoltages on the DC bus drive
  • line supply overvoltage drive
  • line supply undervoltage drive
  • line supply phase loss drive
  • overspeed drive
  • break on the control circuit drive
Sampling Duration
  • 2 ms +/- 0.5 ms DI1...DI8) - discrete input
  • 5 ms +/- 1 ms DI7, DI8) - pulse input
  • 1 ms +/- 1 ms AI1, AI2, AI3) - analog input
  • 5 ms +/- 1 ms AQ1, AQ2) - analog output
Linearity Error
  • AI1, AI2, AI3 +/- 0.15 % of maximum value analog input
  • AQ1, AQ2 +/- 0.2 % analog output
Environmental Class During Operation
  • class 3C3 according to IEC 60721-3-3
  • class 3S3 according to IEC 60721-3-3
Persona Type Names
  • End User
  • Original Equipment Manufacturer
  • OEM - Control Panelbuilder
  • System Integrator
Motor Power KW
  • 4.0 kW normal duty
  • 3.0 kW heavy duty
Refresh Time
  • relay output R1, R2, R3)5 ms +/- 0.5 ms)
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 4 492 kg CO2 eq.
  • 4491.5380852373
Electromagnetic Compatibility
  • electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
  • radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
  • electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
  • 1.2/50 s - 8/20 s surge immunity test level 3 conforming to IEC 61000-4-5
  • conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Apparent Power
  • 5.6 kVA 480 V normal duty)
  • 4.5 kVA 480 V heavy duty)
Persona Type Ids
  • EU
  • OM
  • OM8
  • SI
Environmental Class During Transport
  • class 2C3 according to EN 60721-3-2
  • class 2S1 according to EN 60721-3-2
Number Of Addresses
  • 1-247 Modbus serial
Maximum THDI
  • <48 % full load IEC 61000-3-12
Carbon Footprint Of The Distribution Phase A4
  • 0.8257447414
  • 0.8 kg CO2 eq.
Synchronous Motor Control Profile
  • permanent magnet motor
  • synchronous reluctance motor
Minimum Switching Current
  • relay output R1, R2, R3 5 mA 24 V DC
Operating Altitude
  • <= 3280.84 ft (1000 m) without derating
  • 1000...4800 m with current derating 1 % per 100 m
Noise Level
  • 54.5 dB 86/188/EEC
Asynchronous Motor Control Profile
  • optimized torque mode
  • constant torque standard
  • variable torque standard
Discrete Output Type
  • logic output DQ+ 0-1 kHz <= 30 V DC 100 mA
  • programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA
  • logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Maximum Transient Current
  • 11.2 A 60 s normal duty)
  • 10.8 A 60 s heavy duty)
Power Dissipation In W
  • natural convection 33 W 380 V 4 kHz
  • forced convection 97 W 380 V 4 kHz
Transmission Rate
  • 10/100 Mbit/s Ethernet IP/Modbus TCP
  • 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Ambient Air Temperature For Operation
  • -15-50 °C (without derating)
  • 50-60 °C (with derating factor)
UE Rated Operational Voltage
  • 380...480 V 4.0 kW 5 hp normal duty
  • 380...480 V 3.0 kW heavy duty
Data Format
  • 8 bits, configurable odd, even or no parity Modbus serial
Switching Frequency
  • 2...16 kHz adjustable
  • 4...16 kHz with derating factor



Compare