Image thumbnail 1
Image thumbnail 2
Image thumbnail 3
Image thumbnail 4
Image thumbnail 5

Email

Square D XALK178GH7 CONTROL STN E-STOP TRIGGER ACTION

Manufacturer: Square-D / Schneider | Catalog # XALK178GH7 | Cooper Electric Part # 1195193

$177.14 /ea
ea
Log in or register to view your price, purchase history, and more!
Out of stock, please contact your sales representative for availability, pricing and lead times
This Harmony XALK yellow control station for emergency stop function is ideal for your complete control station. It operates with turn to release mechanism and uses screw-clamp terminals. This control station with mushroom head push button for emergency stop function is ideal for situations where quick actions are required for a process or machine to function correctly or where operator movements require maximum ergonomy. Its schematic is clearly distinguishable thanks to clear colors. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP65, making it ideal for operation in harsh environments. Its wide range of operating temperatures from -40.C to 70.C allows versatility in usage of product. Vibration resistant screw clamp connection terminals ensure high vibration resistance making product suitable installation on high impact machine.

Technical Information

Action
SLOW-BREAK
Actuator
1 MUSHROOM HEAD PUSH-BUTTON,1 MUSHROOM HEAD Ø 40 MM PUSH-BUTTON, RED 1 NO + 2 NC UNMARKED,RED UNMARKED 1 NO + 2 NC
Amperage
3 Amp 240 V, AC-15, A600 EN/IEC 60947-5-1-6 Amp 120 V, AC-15, A600 EN/IEC 60947-5-1-0.1 Amp 600 V, DC-13, Q600 EN/IEC 60947-5-1-0.27 Amp 250 V, DC-13, Q600 EN/IEC 60947-5-1-0.55 Amp 125 V, DC-13, Q600 EN/IEC 60947-5-1-1.2 Amp 600 V, AC-15, A600 EN/IEC 60947-5-1
Applications
FOR XB5 Ø 22 MM CONTROL AND SIGNALLING UNITS
Cable Entry
0-14 mm
Contact Material
Silver Alloy
Enclosure
NEMA 13-NEMA 4X
Material
Polycarbonate
Net Weight
0.194 kg
Operating Force
44 N
Operating Temperature
-40-70 Adegrees C
Size
22MM
Standard
CSA C22.2 No 14,EN/IEC 60204-1,EN/IEC 60947-1,EN/IEC 60947-5-1,EN/IEC 60947-5-4,EN/IEC 60947-5-5,EN/ISO 13850,IEC 60364-5-53,JIS C 4520,UL 508
Storage Temperature
-40-70 degrees C
TC Connection
SCREW CLAMP TERMINALS, <= 2 X 1.5 MMA WITH CABLE END EN/IEC 60947-1-SCREW CLAMP TERMINALS, >= 1 X 0.22 MMA WITHOUT CABLE END EN/IEC 60947-1
Type
COMPLETE CONTROL STATION

Manufacturer Information

Brand
Schneider Electric
Sub Brand
XALK

General Product Info

12-Digit UPC
389119413957
GTiN
03389119413954
Product UPC
78590183479
Weight
0.194 kg

Dimensions

Warranty Length
18 mth

Certifications and Compliance

CA Prop65 Warning
This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
Certifications
CSA,UL Listed
Country of Origin
Czechia
Connections Terminals
  • screw clamp terminals, <= 2 x 1.5 mm² with cable end IEC 60947-1
  • screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1
Overvoltage Category
  • class II conforming to IEC 60536
Color Of Base Of Enclosure
  • light grey RAL 7035)
IE Rated Operational Current
  • 3 A 240 V, AC-15, A600 IEC 60947-5-1
  • 6 A 120 V, AC-15, A600 IEC 60947-5-1
  • 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1
  • 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1
  • 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1
  • 1.2 A 600 V, AC-15, A600 IEC 60947-5-1
ITH Conventional Free Air Thermal Current
  • 10 A IEC 60947-5-1
IP Degree Of Protection
  • IP66 IEC 60529
  • IP67
  • IP69
  • IP69K
Shape Of Screw Head
  • cross Philips no 1
  • cross pozidriv No 1
  • slotted flat Ø 4 mm
  • slotted flat Ø 5.5 mm
Carbon Footprint Of The Installation Phase A5
  • 0.0011702419
  • 0 kg CO2 eq.
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 0 kg CO2 eq.
  • 0.0366325426
Cable Entry
  • 1 knock-out for cable entry 0-14 mm
  • 2 knock-outs for Pg 13 cable gland and ISO M20 0-12 mm
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 1 kg CO2 eq.
  • 1.2626794819
Nema Degree Of Protection
  • NEMA 13
  • NEMA 4X
UI Rated Insulation Voltage
  • 600 V 3)IEC 60947-1
Electrical Durability
  • 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
  • 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
  • 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
  • 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
  • 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
Operating Force
  • 44 N NC + NO changing electrical state
Vibration Resistance
  • 5 gn (f= 12-500 Hz) conforming to IEC 60068-2-6
Market Segmentation
  • Commercial
  • Industrial
Color Of Cover
  • yellow RAL 1021)
Positive Opening
  • with IEC 60947-5-1 appendix K
Persona Type Names
  • Charge Point Operator
  • End User
  • Contractor
  • Original Equipment Manufacturer
  • OEM - Control Panelbuilder
  • Panel Builder
  • Electrician
  • System Integrator
  • IT Channel Partner
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 0.2 kg CO2 eq.
  • 0.1828392
Persona Type Ids
  • BM9
  • EU
  • LC
  • OM
  • OM8
  • PB
  • SC
  • SI
  • VR
Carbon Footprint Of The Distribution Phase A4
  • 0.025030893
  • 0 kg CO2 eq.
Tightening Torque
  • 0.8-1.2 N.m IEC 60947-1
Resistance To High Pressure Washer
  • 7000000 Pa 55 °C 0.1 m
Short Circuit Protection
  • 10 A cartridge fuse gG IEC 60947-5-1
Control Station Composition
  • 1 mushroom head Ø 40 mm push-button, red 1 NO + 2 NC unmarked
Operating Travel
  • 1.5 mm NC changing electrical state)
  • 2.6 mm NO changing electrical state)
  • 4.3 mm total travel)
Market Segmentation Id
  • COMMERCIAL
  • INDUSTRIAL
Electrical Reliability
  • ? < 10exp(-6) 5 V, 1 mA IEC 60947-5-4
  • ? < 10exp(-8) 17 V, 5 mA IEC 60947-5-4
Shock Resistance
  • 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27
  • 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
UIMP Rated Impulse Withstand Voltage
  • 6 kV IEC 60947-1



Compare