This Schneider Electric Zelio Logic SR2B compact smart relay / programmable controller uses a supply voltage of 12 volts direct current, has 20 inputs / outputs with screw-clamp terminals, has an integrated clock and LCD display. This compact programmable relay is ideal for management, remote control or monitoring of simple automation systems. It is suitable for both industrial and commercial applications. It has compact form-factor, allowing installation on DIN rail. It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons. Simple ladder programming, adapted for non-specialists. Discovery package, coming with Zelio Soft programming software, the simplest way to learn and use this relay. Built-in EEPROM flash memory for data backup up to 10 years, easy-to-recover after a power shortage or incident. The main application of this module is industry and building/service sector. This product is certified by C-Tick, GL, UL, CSA and GOST. It meets EN/IEC 60068-2-6 Fc and EN/IEC 61000-4-11 standards. Easy to use, Zelio Logic provides a real alternative solutions based on cabled logic or specific cards.

Technical Information

Amperage
200 MA WITHOUT EXTENSION)
Contact Configuration
NO RELAY OUTPUT
Contact Rating
>= 10 MA 12 V RELAY OUTPUT)
Enclosure
IP20 (TERMINAL BLOCK) CONFORMING TO IEC 60529-IP40 (FRONT PANEL) CONFORMING TO IEC 60529
Net Weight
0.38 kg
Number of Outputs
8 Relay
Operating Cycles
0.1 HZ AT IE)RELAY OUTPUT-10 HZ NO LOAD)RELAY OUTPUT
Operating Temperature
-20-40 degrees C In Non-ventilated Enclosure IEC 60068-2-1 And IEC 60068-2-2 || -20-55 degrees C IEC 60068-2-1 And IEC 60068-2-2
Response Time
10 ms from state 0 to state 1)relay output;5 ms from state 1 to state 0)relay output
Size
COMPACT
Standard
IEC 60068-2-27 Ea,IEC 60068-2-6 Fc,IEC 61000-4-11,IEC 61000-4-12,IEC 61000-4-2 Level 3,IEC 61000-4-3,IEC 61000-4-4 Level 3,IEC 61000-4-5,IEC 61000-4-6 Level 3
Storage Temperature
-40-70 degrees C
TC Connection
SCREW TERMINALS, 1 X 0.2...1 X 2.5 MMA AWG 25...AWG 14) SEMI-SOLID-SCREW TERMINALS, 1 X 0.2...1 X 2.5 MMA AWG 25...AWG 14) SOLID-SCREW TERMINALS, 1 X 0.25...1 X 2.5 MMA AWG 24...AWG 14) FLEXIBLE WITH CABLE END-SCREW TERMINALS, 2 X 0.2...2 X 1.5 MMA AWG 24...AWG 16) SOLID-SCREW TERMINALS, 2 X 0.25...2 X 0.75 MMA AWG 24...AWG 18) FLEXIBLE WITH CABLE END
Type
Compact smart relay

Manufacturer Information

Brand
Schneider Electric
Sub Brand
ZELIO LOGIC 2

General Product Info

12-Digit UPC
338911054974
Environmental Conditions
EMC DIRECTIVE EN/IEC 61000-6-2-EMC DIRECTIVE EN/IEC 61000-6-3-EMC DIRECTIVE EN/IEC 61000-6-4-EMC DIRECTIVE EN/IEC 61131-2 ZONE B-LOW VOLTAGE DIRECTIVE EN/IEC 61131-2
GTiN
03389110549720
Product UPC
78590142265
Weight
0.38 kg

Dimensions

Warranty Length
18 mth

Certifications and Compliance

CA Prop65 Warning
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Certifications
C-tick,CSA,GL,GOST,UL
Country of Origin
France
Contacts Type And Composition
  • NO relay output
US Rated Supply Voltage
  • 12 V DC
Connections Terminals
  • screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid
  • screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 1
Overvoltage Category
  • III conforming to IEC 60664-1
Clock Drift
  • 12 min/year 0-55 °C
  • 6 s/month 25-25 °C
Number Or Control Scheme Lines
  • 0-240 ladder
  • 0-500 FBD
IP Degree Of Protection
  • IP20 IEC 60529 terminal block)
  • IP40 IEC 60529 front panel)
Prop 65
  • WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Mechanical Durability
  • 10000000 cycles relay output
Response Time
  • 10 ms from state 0 to state 1)relay output
  • 5 ms from state 1 to state 0)relay output
Carbon Footprint Of The Installation Phase A5
  • 0.1 kg CO2 eq.
  • 0.06765374140097223
Carbon Footprint Of The End Of Life Phase C1 To C4
  • 0.9015625862184546
  • 0.9 kg CO2 eq.
Disturbance Radiated Conducted
  • class B EN 55022-11 group 1
LSB Value
  • 39 mV analogue input circuit
Carbon Footprint Of The Manufacturing Phase A1 To A3
  • 44 kg CO2 eq.
  • 44.10239030927512
Switching Capacity In MA
  • >= 10 mA 12 V relay output)
Input Compatibility
  • 3-wire proximity sensors PNP discrete input
Immunity To Microbreaks
  • 10 ms repeated 20 times
Electrical Durability
  • AC-12 500000 cycles 230 V, 1.5 A relay output IEC 60947-5-1
  • AC-12 500000 c
Voltage State 1 Guaranteed
  • >= 7 V IB...IG used as discrete input circuit
  • >= 5.6 V I1...IA and IH...IR discrete input circuit
Discrete Input Voltage
  • 12 V DC
Environmental Characteristic
  • EMC directive conforming to IEC 61000-6-2
  • EMC directive conforming to IEC 61000-6-3
  • EMC directive conforming to IEC 61000-6-4
  • EM
Carbon Footprint Of The Use Phase B2 B3 B4 B6
  • 104 kg CO2 eq.
  • 104.12914339137592
Conversion Time
  • smart relay cycle time analogue input circuit
Number Of Outputs
  • 8 relay
Relative Humidity
  • 95-95 % without condensation or dripping water
Operating Distance
  • 10 m between stations, with screened cable (sensor not isolated) analogue input circuit
  • 10 m between stations, with screened cable (sensor not isolated) analogue inpu
Current State 0 Guaranteed
  • <= 0.9 mA I1...IA and IH...IR discrete input circuit)
  • <= 0.9 mA IB...IG used as discrete input circuit)
Output Voltage Limits
  • 24...250 V AC relay output)
  • 5...30 V DC relay output)
Carbon Footprint Of The Distribution Phase A4
  • 0.7147161661008263
  • 0.7 kg CO2 eq.
Repeat Accuracy
  • +/- 2 % 55 °C analogue input circuit
Operating Rate In HZ
  • 0.1 Hz at Ie)relay output
  • 10 Hz no load)relay output
Output Thermal Current
  • 8 A for all 8 outputs relay output
Counting Frequency
  • 1 kHz discrete input
Maximum Permissible Voltage
  • 14.4 V analogue input circuit
Conversion Error
  • +/- 5 % 25 °C analogue input circuit
  • +/- 6.2 % 55 °C analogue input circuit
Maximum Supply Current
  • 200 mA without extension)
Voltage State 0 Guaranteed
  • <= 3 V IB...IG used as discrete input circuit
  • <= 2.4 V I1...IA and IH...IR discrete input circuit
Input Impedance
  • 14 kOhm IB...IG used as analogue input circuit
  • 14 kOhm IB...IG used as discrete input circuit
  • 2.7 kOhm I1...IA and IH...IR discrete input circuit
  • 2.7 kOhm I1...
Power Dissipation In W
  • 2.5 W without extension
Current State 1 Guaranteed
  • >= 2 mA I1...IA and IH...IR discrete input circuit)
  • >= 0.5 mA IB...IG used as discrete input circuit)
Ambient Air Temperature For Operation
  • -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2
  • -20-55 °C IEC 60068-2-1 and IEC 60068-2-2
  • -2
Discrete Input Number
  • 12 IEC 61131-2 Type 1
UIMP Rated Impulse Withstand Voltage
  • 4 kV EN/IEC 60947-1 and EN/IEC 60664-1